1.
IEEE Trans Biomed Eng ; 71(2): 446-455, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37603484

RESUMO

OBJECTIVE: Total artificial hearts (TAH) serve as a temporary treatment for severe biventricular heart failure. The limited durability and complication rates of current devices hamper long-term cardiac replacement. The aim of this study was to assess the feasibility of a novel valveless pumping principle for a durable pulsatile TAH (ShuttlePump). METHODS: The pump features a rotating and linearly shuttling piston within a cylindrical housing with two in- and outlets. With a single moving piston, the ShuttlePump delivers pulsatile flow to both systemic and pulmonary circulation. The pump and actuation system were designed iteratively based on analytical and in silico methods, utilizing finite element methods (FEM) and computational fluid dynamics (CFD). Pump characteristics were evaluated experimentally in a mock circulation loop mimicking the cardiovascular system, while hemocompatibility-related parameters were calculated numerically. RESULTS: Pump characteristics cover the entire required operating range for a TAH, providing 2.5-9 L/min of flow rate against 50-160 mmHg arterial pressures at stroke frequencies of 1.5-5 Hz while balancing left and right atrial pressures. FEM analysis showed mean overall copper losses of 8.84 W, resulting in a local maximum blood temperature rise of <2 K. The CFD results of the normalized index of hemolysis were 3.57 mg/100 L, and 95% of the pump's blood volume was exchanged after 1.42 s. CONCLUSION AND SIGNIFICANCE: This study indicates the feasibility of a novel pumping system for a TAH with numerical and experimental results substantiating further development of the ShuttlePump.


Assuntos
Insuficiência Cardíaca , Coração Artificial , Coração Auxiliar , Humanos , Pressão Arterial , Fluxo Pulsátil
2.
ASAIO J ; 70(2): 107-115, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831817

RESUMO

Effective treatment of heart failure with preserved ejection fraction (HFpEF) remains an unmet medical need. Although left atrial decompression using mechanical circulatory support devices was previously suggested, the heterogeneous HFpEF population and the lack of tailored devices have prevented the translation into clinical practice. This study aimed to evaluate the feasibility of left atrial decompression in HFpEF patients with a HeartMate 3 (HM3, Abbott Inc, Chicago, USA) in silico and in vitro . Anatomic compatibility of the HM3 pump was assessed by virtual device implantation into the left atrium through the left atrial appendage (LAA) and left atrial posterior wall (LAPW) of 10 HFpEF patients. Further, the efficacy of left atrial decompression was investigated experimentally in a hybrid mock loop, replicating the hemodynamics of an HFpEF phenotype at rest and exercise conditions. Virtual implantation without substantial intersection with surrounding tissues was accomplished through the LAA in 90% and 100% through the LAPW. Hemodynamic analysis in resting conditions demonstrated normalization of left atrial pressures without backflow at a pump speed of around 5400 rpm, whereas a range of 6400-7400 rpm was required during exercise. Therefore, left atrial decompression with the HM3 may be feasible in terms of anatomic compatibility and hemodynamic efficacy.


Assuntos
Apêndice Atrial , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Volume Sistólico , Átrios do Coração/cirurgia , Hemodinâmica , Descompressão , Função Ventricular Esquerda
3.
ASAIO J ; 69(11): 1016-1024, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37902686

RESUMO

Several device designs for cavopulmonary mechanical circulatory support (MCS) are under investigation, however, challenged by the Fontan population's heterogeneity in size, cardiovascular and thoracic anatomy. This study aimed to preclinically assess the anatomical compliance of proposed device designs in silico. Representative double- and single-outlet cavopulmonary assist device (CPAD) designs were virtually implanted into CT imaging data of 10 patients previously palliated with total cavopulmonary connection (TCPC) for functionally univentricular hearts. Anatomical device compatibility was characterized concerning pump proximity to cardiovascular, respiratory and thoracic structures, as well as pump in- and outflow graft configuration. In 10 Fontan patients with a median age of 10.4 years (interquartile range [IQR] 5.0-15.3 years) and a median body surface area of 1.09 m2 (IQR 0.76-1.28 m2), implantation of a double-outlet CPAD was feasible in 1 patient (10%). In all other, adverse device intersection with the trachea and (neo-)aorta, or posterior pulmonary artery outflow graft kinking were observed. A single-outlet design permitted enhanced device mobilization adapting to individual anatomical conditions, resulting in device fit in nine of 10 patients (90%). Despite vast anatomical variations among single ventricle patients, a single-outlet device design may provide intracorporeal cavopulmonary MCS to a broad spectrum of failing Fontan patients.


Assuntos
Aorta , Artéria Pulmonar , Humanos , Pré-Escolar , Criança , Adolescente , Superfície Corporal , Cooperação do Paciente , Pacientes